Octopus® 900
The most versatile Perimeter
The Octopus 900 is the all-in-one perimeter with astounding productivity for demanding practices, busy clinics and university hospitals.
- All-in-One Perimeter: Standard Automated Perimetry, SWAP, Flicker and Goldmann Kinetik
- Fastest Test Strategy: Full threshold test within 2:30 minutes
- Goldmann Kinetic: Official successor to the original Goldmann perimeter
- Reliability: True fixation control and automated Eye Tracking
- Networkability: Ethernet connection and EMR interface
|
|
|
White/White, Blue/Yellow, Flicker and Goldmann Kinetic Perimetry
The Octopus 900 Pro covers the whole range of glaucoma detection and follow up with standard white/white perimetry, blue/yellow (SWAP - Short wavelength automated perimetry) and Flicker (critical flicker fusion perimetry) for early detection plus real Goldmann Kinetic Perimetry.
Fastest test strategy
The exclusive TOP test strategy finishes a threshold test in 2:30 minutes, providing excellent repeatability for the usage in follow up and progression analysis. TOP is the preferred test strategy chosen by patients and can even be reliably performed in children age 7 and up.
Real Goldmann Kinetic Perimetry GKP
The Octopus 900 is the official successor to the original Haag-Streit Goldmann perimeter. With it's true Goldmann size and shape cupola it performs accurate manual and automated Goldmann perimetry. Plus, GKP includes age matched normal values for better diagnosis, reaction time compensation and an EMR interface.
Reliability with fixation control
Displacements and blinks influence the examination in realtime. If a stimulus presentation interferes with a blink, the corresponding response is ignored and the same stimulus presentation repeated later in the test.
Speed up with Automated Eye Tracking
Automated Eye Tracking - AET - readjusts the patients position every time the patient moves too far from the center of the refractive lens. Therefore, AET minimizes the risk for lens rim artefacts and saves time by minimizing the need for examiner interventions.
Lens distance measurement
To prevent lens rim artifacts, the refractive lens needs to be close enough to the eye during any test. The Octopus 900 provides a measurement function to warn if the lens is too far off.
Save time with the "follow up" button
Once you select a patient, the instrument displays a single button that selects the same examinations, stratregies and other parameters the patient was examined with the last time. This way you save time with the set up and ensure you have matching data for superior progression analysis.